Laboratory Clean Room Equipment Biosafety Cabinet Burst - Proof Window SS Tank
Product Details:
Place of Origin: | China |
Brand Name: | SUCLAB |
Certification: | SEFA SGS ISO9001 ISO14001 OHSAS |
Model Number: | standard |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 pcs |
---|---|
Price: | negotiation |
Packaging Details: | Export Packing |
Delivery Time: | 1 5working days |
Payment Terms: | TT LC |
Supply Ability: | more than 10000 pcs per month |
Detail Information |
|||
High Light: | class ii a2 biosafety cabinet,horizontal laminar flow clean bench |
---|
Product Description
Biosafety Cabinet Manufacturer / Biological Safety Cabinet Types / Biosafety Cabinet Price
Features of Biosafety Cabinet Class A2:
1. Front window: when using optical perspective is clear, clean and disinfect does not negatively
impact burst-proof tempered glass, tempered glass production, glass thickness ≥ 5 mm.
2. Cabinet: four two-tier structure, all Studio and the collecting tank to use imports 304 stainless
steel materials.
3. Operations on three sides and side wall panels unibody structure, leave some space
at the bottom, easy to clean, to avoid cross infection.
4. Blower / motor maintenance and disassembly, replacement HEPA filters are available from all
safety cabinets.
5. Containment of the Cabinet: the cabinets pressurized to 500Pa, keep the air pressure
is not lower than 450Pa after 30min.
6. Cabinet stability: a countertop Center load 23kg unload, countertop must not bend downward.
7. Alarm system: safety Cabinet front window opening height exceeds a set level, decreased
safety Cabinet flow velocity and flow fluctuation of air flow velocity in excess of their nominal
value of 20%, the interlocking system startup, sound, light, sound and alarm.
8. HEPA filter integrity: scan filter at any point of the leak rate of less than 0.01%.
9. Cannot scan filters detect leak rate of less than 0.005% personal protection: percussive
sampler number ≤ 10CFU/.
10. Slit type sampler number ≤ 5CFU/product protection: colony count ≤ 5CFU/cross
infection: colony count ≤ 2CFU/.
Technical Parameters of Biosafety Cabinet Class A2:
Product name |
Biosafety Cabinet Class A2 |
||
Index/type technical parameter |
HZJBSC-1100-LⅡA2 |
HZJBSC-1360-LⅡA2 |
HZJBSC-1800IIA2 |
Exhaust volume |
30% exhaust |
||
HEPA filter leakage ratio |
≤0.005% |
||
Wind speed |
Inflows flow average wind speed: >0.5M/s Downdrafts in average wind speed: 0.25-0.5 m/s |
||
Noise |
≤62dB(A) |
||
Semi-peak |
≤3μm(rms) |
||
Illumination |
≥700LX |
||
Display |
LCD + remote control |
||
Power supply |
Single AC 220V/50Hz |
||
Normal power consumption |
0.85kw |
||
Max power consumption |
1.85kw (including two spare socket 1000W) |
||
Weight |
305kg |
320kg |
326kg |
Workspace dimensions |
1220x600x680mm |
1360x600x680mm |
1800x600x680mm |
Device overall dimension |
1382x790x2150mm |
1525x790x2150mm |
1940x790x2150mm |
Air filter specifications and quantity |
1215x500x50mmx① |
1355x500x50mmx① |
1795x500x50mmx① |
Exhaust air filter specifications and quantity |
600x440x90mmx① |
740x400x90mmx① |
865x440x90mmx① |
Fluorescent lights/UV lamps specifications and quantity |
30w×②/30w×① |
40w×②/40w×① |
40w×②/40w×① |
The number of applicable |
Single double single |
Double single |
More than single-sided |