Four / Two Tier Clean Room Equipment , 1382x790x2150mm Biosafety Hood Level 2
Product Details:
Place of Origin: | China |
Brand Name: | SUCLAB |
Certification: | SEFA SGS ISO9001 ISO14001 OHSAS |
Model Number: | standard |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 pcs |
---|---|
Price: | negotiation |
Packaging Details: | Export Packing |
Delivery Time: | 1 5working days |
Payment Terms: | TT LC |
Supply Ability: | more than 10000 pcs per month |
Detail Information |
|||
Size: | 1382x790x2150mm | Material: | Full Steel |
---|---|---|---|
Color: | White | Uv Lamp: | 1 Pcs |
Air Flow Velocity: | >0.35 M/s | ||
Highlight: | class ii a2 biosafety cabinet,cleanroom pass through box |
Product Description
Clean Room Grade 2 Biosafety Cabinet Price
Features of Grade 2 Biosafety Cabinet:
1. Cabinet: four two-tier structure, all Studio and the collecting tank to use imports 304 stainless
steel materials.
2. Operations on three sides and side wall panels unibody structure, leave some space
at the bottom, easy to clean, to avoid cross infection.
3. Blower/motor maintenance and disassembly, replacement HEPA filters are available from all
safety cabinets.
4. Cabinet stability: a countertop Center load 23kg unload, countertop must not bend downward.
5. Alarm system: safety Cabinet front window opening height exceeds a set level,
decreased safety Cabinet flow velocity and flow fluctuation of air flow velocity
in excess of their nominal value of 20%, the interlocking system startup, sound,
light, sound and alarm.
6. Containment of the Cabinet: the cabinets pressurized to 500Pa,
keep the air pressure is not lower than 450Pa after 30min.
7. HEPA filter integrity: scan filter at any point of the leak rate of less than 0.01%.
8. Cannot scan filters detect leak rate of less than 0.005% personal protection: percussive
sampler number ≤ 10CFU/.
9. Slit type sampler number ≤ 5CFU/product protection: colony count ≤ 5CFU/cross
infection: colony count ≤ 2CFU/.
Technical Parameters of Grade 2 Biosafety Cabinet:
|
Grade 2 Biosafety Cabinet |
||
Index/type technical parameter |
HZJBSC-1100-LⅡA2 |
HZJBSC-1360-LⅡA2 |
HZJBSC-1800IIA2 |
Exhaust volume |
30% exhaust |
||
HEPA filter leakage ratio |
≤0.005% |
||
Wind speed |
Inflows flow average wind speed: >0.5M/s |
||
Noise |
≤62dB(A) |
||
Semi-peak |
≤3μm(rms) |
||
Illumination |
≥700LX |
||
Display |
LCD + remote control |
||
Power supply |
Single AC 220V/50Hz |
||
Normal power consumption |
0.85kw |
||
Max power consumption |
1.85kw (including two spare socket 1000W) |
||
Weight |
305kg |
320kg |
326kg |
Workspace dimensions |
1220x600x680mm |
1360x600x680mm |
1800x600x680mm |
Device overall dimension |
1382x790x2150mm |
1525x790x2150mm |
1940x790x2150mm |
Air filter specifications |
1215x500x50mmx① |
1355x500x50mmx① |
1795x500x50mmx① |
Exhaust air filter specifications |
600x440x90mmx① |
740x400x90mmx① |
865x440x90mmx① |
Fluorescent lights/UV lamps |
30w×②/30w×① |
40w×②/40w×① |
40w×②/40w×① |
The number of applicable |
Single double single |
Double single |
More than |